簡單的說,電機轉(zhuǎn)矩是指其轉(zhuǎn)動力量的大小,是電機拖動負載能力的具體表現(xiàn)。在電機產(chǎn)品的性能參數(shù)中,以額定轉(zhuǎn)矩、轉(zhuǎn)矩和轉(zhuǎn)矩表征其不同狀態(tài)下的性能指標。

 

轉(zhuǎn)矩是電機起動性能的特性,額定轉(zhuǎn)矩是電機額定運行條件下對應(yīng)的力能指標,而轉(zhuǎn)矩則反映電機的過載能力;不同的產(chǎn)品特性和使用工況對轉(zhuǎn)矩的要求不同。

 

對照同中心高、同功率但不同極數(shù)的電機可以發(fā)現(xiàn),多極低轉(zhuǎn)速電機的轉(zhuǎn)矩較大,在電機的短路試驗中可以發(fā)現(xiàn),較小規(guī)格的少極電機,制動相對容易,而多極的低轉(zhuǎn)速電機制動就比較困難。從電機的外觀特征比較,除特別小或特別大的規(guī)格電機外,同樣中心高同功率的電機,低速電機的軸伸直徑比較大,因為其運行中承載的負載要比較大,這也是針對于電機轉(zhuǎn)矩特性的尺寸保證要求。

 

從電機轉(zhuǎn)矩的計算公式(T=9550 P / n )可以看出,當電機功率相同時,低速電機對應(yīng)的轉(zhuǎn)矩較大。

 

電機軸伸是傳動的關(guān)鍵零部件,除電機與設(shè)備的對接尺寸控制外,電機軸伸的直徑大小、軸的材質(zhì),以及具體的加工控制要求,都直接影響著電機的轉(zhuǎn)矩能力體現(xiàn),是一種機械能力表現(xiàn)。

 

當電機的轉(zhuǎn)矩超過其可以承當?shù)姆秶鷷r,即電機發(fā)生過載,電機的電流會因為過載出現(xiàn)大幅增加,導(dǎo)致繞組發(fā)生過熱燒毀問題;即使電機繞組能滿足過載要求,就電機的軸而言,過載意味阻力矩大,作用在軸上力矩太大時,會對軸伸造成直接的傷害,特別是對于軸伸加工不太規(guī)范的情況,容易發(fā)生電機軸伸撓曲或斷裂的質(zhì)量事故。



ABB PDD205A0121 3BHE025335R0121/3BHE025336P201REVD 廈門雄霸電子

Any electrical product, including motor products, has specified the rated voltage for its normal operation, and any voltage deviation will cause adverse consequences to the normal operation of the electrical appliance.
For relatively high-end equipment, necessary protective devices are used. When the power supply voltage is abnormal, the power supply is cut off for protection. For very precise instruments, constant voltage power supply is used for adjustment. However, for motor products, especially industrial motor products, the possibility of using constant voltage devices is very small, and there are more situations of power outage protection.
For single-phase motors, there are only two types of voltage: high and low, while for three-phase motors, there is also a voltage balance problem. The direct impact of these three voltage deviations is an increase in current or an imbalance in current.
According to the technical specifications of the motor, the deviation between the rated voltage of the motor cannot exceed 10%, and the torque of the motor is proportional to the square of the motor terminal voltage. When the voltage is too high, the motor core will be in a magnetic saturation state, and an increase in stator current will cause serious heating of the winding, even leading to quality problems such as winding burnout; For situations where the voltage is low, one possibility is that there may be problems with the starting of the motor, especially for motors operating under load. In order to meet the load operation of the motor, the current must also increase. The consequence of the current increase is also the heating or even burning of the winding, especially for long-term low-voltage operation, which is even more serious.

The voltage imbalance of three-phase motors is a typical power supply problem. When the voltage is unbalanced, it will inevitably lead to the imbalance of motor current. The negative sequence component of unbalanced voltage generates a magnetic field in the motor air gap that is opposite to the rotation of the rotor. The small negative sequence component in the voltage may cause the current flowing through the winding to be much larger than the current at voltage balance. The frequency of the current flowing through the rotor conductor is almost twice the rated frequency, so the current squeezing effect in the rotor conductor causes the increase in losses of the rotor winding to be much greater than that of the stator winding. The temperature rise of the stator winding is higher than that when operating under balanced voltage.
When the voltage is unbalanced, the locked rotor torque, small torque, and large torque of the motor will all decrease. If the voltage imbalance is severe, the motor will not function properly.
When the motor operates at full load under unbalanced voltage, the speed will slightly decrease due to the increase in slip rate as the additional loss of the rotor increases. As the degree of voltage (current) imbalance increases, the noise and vibration of the motor may increase. Vibration may damage the electric motor or the entire drive system.
To effectively identify the cause of uneven motor voltage, methods such as power supply voltage detection or current changes may be used. Most devices are equipped with voltage monitoring instruments, which can be analyzed through data comparison. However, for situations without monitoring devices, regular testing or current measurement should be used; For motors that can rotate in both directions, without affecting the dragged equipment, the two-phase power supply lines can be freely swapped to observe the current changes, and indirectly analyze the voltage balance. After eliminating the problem of uneven voltage, quality issues such as turn to turn and phase to phase may be involved.

 

ABB PDD205A0121 3BHE025335R0121/3BHE025336P201REVD 廈門雄霸電子


推薦產(chǎn)品

如果您有任何問題,請跟我們聯(lián)系!

聯(lián)系我們

Copyright © 2002-2020 廈門雄霸電子商務(wù)有限公司 版權(quán)所有

閩公網(wǎng)安備 35020302034927號

備案號:閩ICP備14012685號

地址:廈門市思明區(qū)呂嶺路1733號萬科創(chuàng)想中心2009室

在線客服 聯(lián)系方式 二維碼

服務(wù)熱線

13313705507

掃一掃,關(guān)注我們

欧美性猛交XXXX乱大交_狂野欧美性猛XXXX乱大交_欧美精品XXXXBBBB_A级大胆欧美人体大胆666_欧美xxxx做受性欧美88